Frequency counter/calibrator (300 MHz/1.3 GHz)
Today's most accurate frequency counter
With a built-in Rubidium atomic resonance-controlled frequency reference, the PM 6685R is the most accurate frequency counter on the market and it has the additional benefit of full portability.
High stability, high accuracy and short warm-up time make this instrument ideal for high-accuracy calibration procedures outside the calibration laboratory environment, such as in base station transmitters of large telecommunications networks like GSM.
The short warm-up time makes that the PM 6685R is ready for use quickly, for example after transport or change of location inside a building.
| PM 6685R Rubidium Counter/Calibrator |
| High-resolution digital frequency counting
Frequency calibration to relative accuracies of better than 1 part in 108 has traditionally required complicated setups, or have been time-consuming to perform, with frequency counters that needed long measuring times to achieve the required resolution. With a virtual clock frequency of 4 GHz, Fluke's PM 6685R offers an unmatched resolution of 2.5 x 10-10 per second, giving 10 reliable read-out digits in only one or a few seconds. This makes high-accuracy calibration measurements possible, with the convenience of requiring only a digital counter. The wide choice of input options allows digital calibration measurements at up to 8 GHz, without the complexity of needing to use synthesizers, mixers and filters to provide the required resolution down to the last digits.
Additionally, digital counting techniques allow a numerical offset or nulling of the display value to make it easy to read changing or arbitrary frequency values with many different digits. Guaranteed high stability for field operation The built-in Rubidium reference solves the practical problems of ensuring very high stability under severe field conditions. The atomic resonance principle of rubidium standards is intrinsically 100 times more stable than an electromechanical crystal resonator; a fact that contributes to making the PM 6685R the most accurate counter/calibrator available for field use. Also, the atomic reference does not suffer from mechanical, thermal, vibrational and line voltage influences in the way that a crystal oscillator would. When carrying a crystal-based counter, for example, just one small bump against a step can cause more frequency change than several months of aging under controlled calibration laboratory conditions. This stronger resistance to environmental stress on the reference permits longer calibration intervals in many practical situations, making the PM 6685R more convenient for field personnel and reducing the cost of ownership. In fact, using the PM 6685R at a field site may even reduce the need to send other elements of a field lab out for their own respective calibration. Rubidium references should therefore be considered for all meaurements or calibrations in the field where accuracies better than a few parts in 108 are required, or where frequent calibration of the counter is not possible. |
| PM 6685R Rubidium Counter/Calibrator | ||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||
|
|
teplota
teplomer
zdroj
vlhkosť
vlhkomer
Automotive
osciloskop
USB
multimeter
DC
záznamník
js
generátor
2chan
PC
True RMS
logger
Fluke
AWG
rosný bod
scopemeter
software
sonda
datalogger
HACCP
transmitter
IR
infračervený
pleseň
EN12830
termokamera
EX
ATEX
4Chan
vpichový
metrologický
12bit
pH
IEEE 488
dmm
GPIB
modulácia
SCC Kit
potraviny
laboratórny
100MHz
4-20mA
komunikácia
IR-Fusion
zadávač
softvér
referenčný
pasterizácia
presný
rozmietanie
SW
objektív
čas
kalibrátor
20MHz
8bit
ATP
200MHz
IP67
stolný
8½
alarm
sterilizácia
LAN
IP68
25MHz
EN285
čitač
digitálny
procesný kalibrátor
bezdrôtový
EN13485
vibrodiagnostika
EN50160
akcelerometer
tabuľka
PS Cumulus Flash tag cloud adapted from the Wordpress original by Roy Tanck requires Flash Player 9 or better. Ported by ecartservice.net.