TG210 - 2MHz Dial-set Function Generator
0.02Hz to 2MHz frequency range
High waveform quality at all frequencies & levels
20mV to 20V pk-pk from 50 Ohms or 600 Ohms
Sine, square and triangle waveforms plus dc
1000:1 frequency change on each range
Variable symmetry control
External sweep input
Three models meeting a variety of needs
The TG210 offers all of the basic generator functions including sine, square & triangle waveforms, variable DC offset, variable symmetry and external sweep input.
Exceptional waveform quality
The TG200 series provides very high waveform quality under all conditions. That means low sinewave distortion, low aberation triangle waves and fast-edged square waves with low overshoot.
Unlike many competitive products good waveform quality is maintained throughout the frequency range, and at low output levels.
All models have bi-directional variable symmetry at constant frequency from 1:9 to 9:1.
Wide range level control
The main output has a maximum emf of 20V pk-pk from a 50Ohm or 600Ohm source. An amplitude vernier with a range of 40dB is combined with a -20dB switched attenuator to provide levels down to 20mV pk-pk. Variable DC offset of +/-10V is available via a centre detent control.
An auxiliary output provides a fixed 0V to +5V level suitable for driving both TTL and CMOS loads.
Wide sweep range
Each range can be swept by at least 1000:1 either manually or via the sweep control input.
| FREQUENCY | |
| Frequency Range: | 0.02Hz to 2MHz in 7 overlapping decade ranges with fine adjustment by a vernier. |
| Vernier Range: | 1000:1 on each range. |
| Vernier Accuracy: | Typically ±5% of full scale. |
| OPERATING MODES | |
| Specifications apply for the top decade of each frequency range and maximum output into 50 termination. |
|
| SINE | |
| Distortion: | <0.5% on 200, 2k and 20k ranges; <1% on 2, 20 and 200k ranges; all harmonics >25dB below fundamental on 2M range. |
| Amplitude Flatness: | ±0.2dB to 200kHz; ±1dB to 2MHz. |
| TRIANGLE | |
| Linearity: | Better than 99% to 200kHz |
| SQUARE WAVE | |
| Rise/Fall Times: | <100ns |
| Mark - Space Ratio: | 1:1 ± 1% to 100kHz |
| DC | |
| Range: | ±10V unterminated |
| SYMMETRY | |
| Symmetry Range: | Variable typically 1:9 to 9:1 (on top decade of each range), frequency divided by 10. |
| OUTPUTS | |
| MAIN - 50 Ohm | |
| Amplitide | 20mV to 20V peak-peak open circuit (10mV to 10V peak-peak into 50Ω) in two switch selectable |
| DC Offset Range: | ±10V from 50Ω. DC offset plus signal peak limited to ±10V (±5V into 50Ω). DC offset plus waveform attenuated proportionally by the attenuator. |
| MAIN - 600 Ohm Alternative output socket offering the same facilities as the 50Ω socket. |
|
| AUX OUT 0 to 5V TTL/CMOS logic levels capable of driving 2 standard TTL loads. Frequency, symmetry and phase as main outputs |
|
| SWEEP (EXTERNAL) | |
| Input Impedance: | 10kΩ |
| Input Sensitivity: | 0 to 3V for 1000:1 sweep |
| Max. Input Voltage: | ±10V |
| Sweep Linearity: | Better than 1% |
| Max. Slew Rate: | 0.1V/us |
| GENERAL | |
| CASING | Moulded ABS case with tilt stand. |
| POWER REQUIREMENTS | |
| Input Voltage: | 220 to 240 volts AC nominal 50/60Hz or 110 to 120 volts AC nominal 50/60Hz by rear panel adjustment. Installation category II. |
| Power Consumption | 25VA max. |
| TEMPERATURE & ENVIRONMENTAL | |
| Operating Temp | +5°C to +40°C, 20% to 80% RH. |
| Storage Temp. | -10°C to +65°C |
| Environmental: | Indoor use at altitudes up to 2000m. Pollution degree 2. |
| Size | 260(W) x 88(H) x 235(D)mm (10.2 x 3.4 x 9.2"), excluding tilt stand and feet. |
| Weight | 1.9kg (4.2lb) |
| Safety | Complies with EN61010-1. |
| EMC | Complies with EN61326. |
|
|
teplota
teplomer
zdroj
vlhkosť
vlhkomer
Automotive
osciloskop
USB
multimeter
DC
záznamník
js
generátor
2chan
PC
True RMS
logger
AWG
Fluke
rosný bod
scopemeter
software
sonda
HACCP
datalogger
transmitter
IR
infračervený
pleseň
EN12830
termokamera
EX
ATEX
4Chan
vpichový
metrologický
12bit
pH
IEEE 488
dmm
GPIB
modulácia
SCC Kit
potraviny
laboratórny
100MHz
4-20mA
komunikácia
IR-Fusion
zadávač
referenčný
pasterizácia
softvér
presný
SW
rozmietanie
objektív
čas
kalibrátor
20MHz
8bit
200MHz
IP67
ATP
8½
stolný
alarm
IP68
25MHz
EN285
sterilizácia
LAN
čitač
digitálny
procesný kalibrátor
bezdrôtový
EN13485
vibrodiagnostika
EN50160
akcelerometer
tabuľka
PS Cumulus Flash tag cloud adapted from the Wordpress original by Roy Tanck requires Flash Player 9 or better. Ported by ecartservice.net.