For secondary level performance with full ITS-90 calibration, Hart’s 5618B series PRTs are an excellent choice for critical temperature measurements. Featuring a 3.2 mm diameter (1/8 in) sheath, these industrial standards probes have reduced response time without compromising precision. This small diameter 5618A probe works well in many applications where immersion depth is limited. Larger diameter probes give more measurement error in short immersion depth applications because they conduct more heat between ambient and the sensor.
With each probe you will receive a full NVLAP-accredited calibration report. On the report you’ll get the test data and the ITS-90 calibration coefficients that you can easily input into your Hart thermometer. If you are using a 1521 Handheld Thermometer readout, we’ll program the coefficients directly into your INFO-CON connector.
The 5618B is also a great probe to use for calibrating your Hart 9132 or 9133 infrared calibrators. In fact, these IR black body heat sources were designed to be calibrated with this type of probe. Now you can calibrate these targets in your own lab!
For use from –200 °C to 500 °C (the six-inch model goes to 300 °C), you won’t find a better industrial standard in this configuration than our 5618B. We recommend using the 5618B PRTs with the 1521, 1522, 1502A, 1529, or 1560 thermometer readouts.
Specifications |
|
|
Resistance |
Nominal 100W at 0 °C |
|
Temperature Coefficient |
0.003923W/W/ °C nominal |
|
Temperature Range |
–200 °C to 500 °C |
|
Drift Rate |
±0.1 °C when used periodically to 500 °C |
|
Sheath Material |
316 SST |
|
Leads |
22 AWG Teflon, 6’ |
|
Termination |
Specify |
|
Hysteresis |
Less than 0.01 °C at 0 °C when using –196 °C and 420 °C as the end points. |
|
Time Constant |
9 seconds max for 63.2 % |
|
Thermal EMF |
Less than 25 mV at 420 °C |
|
Calibration |
Includes NVLAP-accredited calibration w/ITS-90 coefficients, R vs. T values in 1 °C increments |
|
Size |
5618B-12: 305 mm L x 3.2 mm dia. (12 x 1/8 in) 5618B-9: 229 mm L x 3.2 mm dia. (9 x 1/8 in) 5618B-6: 152 mm L x 3.2 mm dia. (6 x 1/8 in) |
|
Probe Accuracy (includes calibration uncertainty and short-term stability) |
±0.05 °C over entire range |
Ordering Information |
|
|
5618B-12-X |
305 mm (12 in) Small Diameter Probe |
|
5618B-9-X |
229 mm (9 in) Small Diameter Probe |
|
5618B-6-X |
152 mm (6 in) Small Diameter Probe |
|
2601 |
Probe Carrying Case |
|
X = termination. Specify “B” (bare wire), “D” (5-pin DIN for Tweener Thermometers), “G” (gold pins), “I” (INFO-CON for 1521 or 1522 Handheld Thermometers), “J” (banana plugs), “L” (mini spade lugs), “M” (mini banana plugs), or “S” (spade lugs). |
|
|
|






























teplota
teplomer
zdroj
vlhkomer
vlhkosť
USB
osciloskop
multimeter
biocote
Automotive
antibakteriálny
záznamník
pyrometer
vodotesný
EN13485
IP65
robustný
IP68
ponorný
cukrársky
generátor
2chan
PC
AWG
True RMS
logger
scopemeter
DC
infračervený
rosný bod
software
Fluke
datalogger
4-20mA
kontaktný
HACCP
kalibrátor
zadávač
sonda
js
wireless
transmitter
IR
4Chan
pleseň
termokamera
vpichový
12bit
dataloger
tlak
metrologický
200MHz
dozimeter
modulácia
dmm
IEEE 488
GPIB
pH
laboratórny
100MHz
potraviny
SCC Kit
termočlánok
komunikácia
IR-Fusion
kvalita siete
softvér
referenčný
pasterizácia
čas
EN50160
presný
LAN
digitálny
odmerka
váha
250MHz
PQ
SW
objektív
analyzátor
PS Cumulus Flash tag cloud adapted from the Wordpress original by Roy Tanck requires Flash Player 9 or better. Ported by ecartservice.net.