Made from the finest platinum and platinum-rhodium alloy, the Type R and Type S Thermocouples cover a temperature range of 0 °C to 1450 °C with uncertainties as good as 0.15 °C over most of that range. With four different models for each type, we have the thermocouple to fit your application.
The measuring junction of both the 5649 and the 5650 is encased in a 0.25-inch (6.35 mm) alumina sheath that can be ordered in lengths of 20 or 25 inches (50.8 or 63.5 cm) to fit the specific requirements of your application. A reference, or “cold,” junction may also be ordered. The reference junction uses a stainless steel sheath and is 8.25 inches long (21 cm) by 0.188 inches in diameter (4.8 mm). The thin diameter minimizes the immersion depth needed, but the extra length ensures you can get all the immersion you like.
Special tin-plated, solid-copper connecting wires with ultra-low EMF properties are used to help retain the integrity of your measurement junction where the probe attaches to your micro voltmeter or Hart Black Stack.
Each probe comes from a spool of wire that has been certified for use with ASTM E-230-03 special tolerances (the greater of ±0.6 °C or ±0.1% of reading over the range 0 °C to 1450 °C). If you need greater accuracy, order an individual fixed-point calibration to reduce uncertainties to ±0.15 °C up to 962 °C, increasing linearly to ±2.0 °C at 1450 °C.
The probe assembly can be easily disassembled for performing your own bare-wire calibrations.
Specifications |
|
|
Range |
0 °C to 1450 °C |
|
Type |
Platinum/13 %Rhodium vs. platinum (type R) |
|
Accuracy† |
Wire is certified for use with ASTM E-230-03 special tolerances (the greater of ±0.6°C or ±0.1% of reading over the range 0°C to 1450°C). An optional fixed-point calibration is available. |
|
Fixed-point Calibration Uncertainty (k=2) |
±0.15°C up to 962 °C, increasing linearly to ±2.0°C at 1450°C |
|
Hot Junction Sheath Dimensions |
6.35 mm (0.25 in) diameter; see Ordering Information for lengths |
|
Reference Junction Sheath Dimensions |
4.8 mm dia. x 210 mm long |
|
Long-Term Stability |
±0.5 °C to 1100 °C |
|
Short-Term Stabilities |
±0.2 °C to 1100 °C |
|
Immersion |
At least 152 mm (6 in) recommended |
|
Protective Case |
Model 2609 case included |
|
Weight |
1 kg (2 lb.) |
| †Does not include short-term stability or long-term stability | |
Ordering Information |
|
| 5649-20-X |
Type R TC, 508 mm (20 in) |
| 5649-20CX |
Type R TC, 508 mm (20 in), with reference junction |
| 5649-25-X |
Type R TC, 635 mm (25 in) |
| 5649-25CX |
Type R TC, 635 mm (25 in), with reference junction |
| 5650-20-X |
Type S TC, 508 mm (20 in) |
| 5650-20CX |
Type S TC, 508 mm (20 in), with reference junction |
| 5650-25-X |
Type S TC, 635 mm (25 in) |
| 5650-25CX |
Type S TC, 635 mm (25 in), with reference junction |
|
X = termination. Specify “B” (bare wire), “W” (generic copper-to-copper TC connector), or “R” (standard Type R/S TC connector). Models with reference junctions should not specify “R” and models without reference junctions should not specify “W”. |
|
| 1918-B |
Four-point calibration by fixed point (Sn, Zn, AI, Ag). |
|
2609 |
Spare Case (for 635 mm [25 in] long TC) |
|
|






























teplota
teplomer
zdroj
vlhkomer
vlhkosť
USB
osciloskop
multimeter
biocote
Automotive
antibakteriálny
záznamník
pyrometer
vodotesný
EN13485
IP65
robustný
IP68
ponorný
cukrársky
generátor
2chan
PC
AWG
True RMS
logger
scopemeter
DC
infračervený
rosný bod
software
Fluke
datalogger
4-20mA
kontaktný
HACCP
kalibrátor
zadávač
sonda
js
wireless
transmitter
IR
4Chan
pleseň
termokamera
vpichový
12bit
dataloger
tlak
metrologický
200MHz
dozimeter
modulácia
dmm
IEEE 488
GPIB
pH
laboratórny
100MHz
potraviny
SCC Kit
termočlánok
komunikácia
IR-Fusion
kvalita siete
softvér
referenčný
pasterizácia
čas
EN50160
presný
LAN
digitálny
odmerka
váha
250MHz
PQ
SW
objektív
analyzátor
PS Cumulus Flash tag cloud adapted from the Wordpress original by Roy Tanck requires Flash Player 9 or better. Ported by ecartservice.net.