If the reason you don’t use fixed-point cells is because they’re too expensive or too difficult to use, you haven’t heard of Hart’s mini fixed-point apparatus.
The triple point of water (0.01 °C) is one of the most important temperatures on the ITS-90. Unfortunately, realizing and maintaining triple point of water cells hasn’t always been convenient or cost-effective.
Because ITS-90 calibrations require frequent measurements at the triple point of water, and because the triple point of water is often used as a statistical check against the drift of a temperature standard, it is important to be able to realize and maintain well-constructed triple point of water cells easily.
Hart’s 9210 TPW Maintenance Apparatus provides built-in programming for the simple supercool-and-shake realization and maintenance of our 5901B Mini TPW Cell. Simply insert the cell, enter the “freeze” mode through the front-panel buttons, have your morning cup of coffee, and when the 9210 audibly alerts you, remove the Mini TPW Cell and give it a shake to initiate freezing a portion of the water. Re-insert the cell, change the program mode to “maintain,” and you’ve got 0.01 °C for the rest of the day with uncertainty of only ±0.0005 °C.
Precision-machined thermal blocks can also be used to take advantage of the excellent stability and uniformity of the 9210 for performing comparison calibrations. Multi-hole and custom blocks are available with 178 mm (7 in) depths.
Specifications |
|
|
Temperature Range |
–10 °C to 125 °C |
|
Ambient Operating Range |
5 °C to 45 °C |
|
Stability |
±0.02 °C |
|
Vertical Gradient |
±0.05 °C over 100 mm at 0 °C |
|
Plateau Duration |
6–10 hours, typical |
|
Resolution |
0.01 ° (0.001 ° in program mode) |
|
Display Scale |
°C or °F, switchable |
|
Immersion Depth |
171 mm (6.75 in) in optional comparison block |
|
Stabilization Time |
15 minutes nominal |
|
Preheat Wells |
3 wells (for 3.18, 6.35, or 7.01 mm probes [0.125, 0.25, 0.276 in]) |
|
Fault Protection |
Adjustable software cutout using control probe; separate circuit thermocouple cutout for maximum instrument temperature |
|
Display Accuracy |
±0.25 °C |
|
Comparison Block |
Three multi-hole blocks, blanks, and custom blocks available |
|
Well-to-Well Gradient (in comparison block) |
±0.02 °C |
|
Heating Time |
Ambient to 100 °C: 45 min. |
|
Cooling Time |
Ambient to –5 °C: 25 min. |
|
Comm. |
RS-232 included |
|
Power Requirements |
115 VAC (±10 %), 60 Hz, 1.5 A, or |
|
Exterior Dimensions |
489 x 222 x 260 mm (19.25 x 8.75 x 10.25 in) |
|
Weight |
7 kg (15.5 lb.) with block |
Ordering Information
|
|
|






























teplota
teplomer
zdroj
vlhkomer
vlhkosť
USB
osciloskop
multimeter
biocote
Automotive
antibakteriálny
záznamník
pyrometer
vodotesný
EN13485
IP65
robustný
IP68
ponorný
cukrársky
generátor
2chan
PC
AWG
True RMS
logger
scopemeter
DC
infračervený
rosný bod
software
Fluke
datalogger
4-20mA
kontaktný
HACCP
kalibrátor
zadávač
sonda
js
wireless
transmitter
IR
4Chan
pleseň
termokamera
vpichový
12bit
dataloger
tlak
metrologický
200MHz
dozimeter
modulácia
dmm
IEEE 488
GPIB
pH
laboratórny
100MHz
potraviny
SCC Kit
termočlánok
komunikácia
IR-Fusion
kvalita siete
softvér
referenčný
pasterizácia
čas
EN50160
presný
LAN
digitálny
odmerka
váha
250MHz
PQ
SW
objektív
analyzátor
PS Cumulus Flash tag cloud adapted from the Wordpress original by Roy Tanck requires Flash Player 9 or better. Ported by ecartservice.net.