The PP198 has been designed to allow fuel injector and primary ignition waveforms to be measured using PicoScope oscilloscope products. Please note this attenuator should not be used for any high voltage measurements other than fuel injectors and primary ignition.
The PP198 is a passive 20:1 attenuator. This means that a 20 V signal at its input will appear as a 1 V signal on the output. As the signal is attenuated, the PP198 allows voltages of up to 300 V to be measured (see the safety precautions).
The PP198, when used with Pico PC Oscilloscopes provides increased input protection against overloads when working with inductive signals such as injectors and primary ignition. Under no circumstances attempt to use this attenuator to measure secondary ignition (HT) waveforms, the PP178 Secondary Ignition Pickup lead should be used for this purpose.
How to Use the 20:1 Attenuator
The PP198 connects in series between the oscilloscope and the test lead (right photograph). The PP198 is only suitable for use with an input channel — it is not suitable for use with an external trigger input.
PicoScope can be configured to work with a 20:1 attenuator probe by selecting first the Settings menu and the the Probes menu. Select 20:1 attenuation for the channel the PP198 is plugged into.
Safety Precautions
The PP198 is designed for measuring automotive signals such as fuel injector and primary ignition voltages (nominally 6, 12 or 24 volts). This attenuator must not be used to measure mains voltages or other hazardous voltages.
Fuel injector and primary ignition signals contain short duration high voltage spikes “inductive kicks”. We therefore recommend the use of two ground connections between the oscilloscope and the vehicle under test. One ground connection is made using the measurement test lead. A second ground lead should be connected between one of the BNC connectors on the oscilloscope and a secure ground point on the vehicle such as the negative terminal of the battery. Misconfiguration and/or failure to follow these warnings may cause damage to the product and/or computer and could cause injury to yourself or others.
| Specifications | |
|---|---|
| Attenuation | 20:1 |
| Input Impedance | 1.053 MΩ |
| Input capacitance | 11 pF |
| Bandwidth | 10 MHz (-3 dB) |
| Max input | 300 V |
|
|






























teplota
teplomer
zdroj
vlhkomer
vlhkosť
USB
osciloskop
multimeter
biocote
Automotive
antibakteriálny
záznamník
pyrometer
vodotesný
EN13485
IP65
robustný
IP68
ponorný
cukrársky
generátor
2chan
PC
AWG
True RMS
logger
scopemeter
DC
infračervený
rosný bod
software
Fluke
datalogger
4-20mA
kontaktný
HACCP
kalibrátor
zadávač
sonda
js
wireless
transmitter
IR
4Chan
pleseň
termokamera
vpichový
12bit
dataloger
tlak
metrologický
200MHz
dozimeter
modulácia
dmm
IEEE 488
GPIB
pH
laboratórny
100MHz
potraviny
SCC Kit
termočlánok
komunikácia
IR-Fusion
kvalita siete
softvér
referenčný
pasterizácia
čas
EN50160
presný
LAN
digitálny
odmerka
váha
250MHz
PQ
SW
objektív
analyzátor
PS Cumulus Flash tag cloud adapted from the Wordpress original by Roy Tanck requires Flash Player 9 or better. Ported by ecartservice.net.