Operation
- Operating temperature -25 to +55°Cand
with derating +70°C
- Incapsulated meets IP20.
- Covection cooled
Features
- Over voltage protectionOVP.
- Extra output with series diode
- Over and under voltage alarm with relay output
- Output voltage adjustment on front panel
EMC
- EN61000-6-3 Emission
- EN61000-6-2 Immunity
- EN/IEC61000-4-4, 4kV.
- EN/IEC61000-4-5 level 2 & 3
Input ratings
Nominal input
|
Input voltage range
|
Stop level
|
Code
|
12 Vd.c.
|
11 - 16V
|
<10 Vd.c.
|
12
|
24 Vd.c.
|
20 - 32V
|
<16,8 Vd.c.
|
24
|
48 Vd.c.
|
40 - 60V
|
<33,6 Vd.c.
|
48
|
Input voltage range: The range where we guaranty full operation, Vout +10%, Aout +5%.
Stop level: The converter works down to the stop level, the output might drop to -10% of nominal output.
Input voltage ranges that meets Railway standard EN50155/IEC60571or other standards, can be provided on request.
Voltage
|
Output current
|
Power
|
13,2V
|
14,1 - 18,9A
|
187 - 250W
|
24V
|
7,8 - 10,4A
|
187 - 250W
|
36V
|
5,2 - 6,9A
|
187 - 250W
|
48V
|
3.9 - 5,2A
|
187 - 250W
|
60V
|
3,1 - 4,2A
|
187 - 250W
|
110V
|
1,7 - 2,3A
|
187 - 250W
|
Output rating and type code
Output
|
Input
|
Voltage
|
Current
|
Power
|
11 - 16V
|
20 - 32V
|
40 - 60V
|
93 - 150V
|
187 - 300V
|
13,2V
|
14,1A
|
187W
|
PM250 12/13,2
|
|
|
|
|
13,2V
|
18,9A
|
250W
|
|
PM250 24/13,2
|
PM250 48/13,2
|
N.A.
|
N.A.
|
24V
|
7,8A
|
187W
|
PM250 12/24
|
|
|
|
|
24V
|
10,4A
|
250W
|
|
PM250 24/24
|
PM250 48/24
|
N.A.
|
N.A.
|
36V
|
5.0A
|
187W
|
PM250 12/36
|
|
|
|
|
36V
|
6,9A
|
250W
|
|
PM250 24/36
|
PM250 48/36
|
N.A.
|
N.A.
|
48V
|
3,9A
|
187W
|
PM250 12/48
|
|
|
|
|
48V
|
5,2A
|
250W
|
|
PM250 24/48
|
PM250 48/48
|
N.A.
|
N.A.
|
60V
|
4,2A
|
187W
|
N.A.
|
|
|
|
|
60V
|
4,2A
|
250W
|
|
N.A.
|
N.A.
|
N.A.
|
N.A.
|
110V
|
1,7A
|
187W
|
N.A.
|
|
|
|
|
110V
|
2,3A
|
250W
|
|
N.A.
|
N.A.
|
N.A.
|
N.A.
|
The available models are indicated
How to read our product code:
E.g. PM250 48/36
PM250 = family code
48 = input voltage code 48
36 = output voltage 36V