General specifications |
General maximum voltage between any terminal and earth ground: 1000V |
Battery |
Type |
2x AA IEC LR6 alkaline |
Battery life |
± 200 hours |
Display |
Dual |
Automatic power off |
After 20 minutes |
AC current: Jaw |
Range |
999,9A |
Resolution |
0,1A |
Accuracy |
2% ± 5 digits (10Hz to 100Hz) 2,5% ± 5 digits (100Hz to 500Hz) |
Crest factor @ 50/60Hz |
3,0 @ 500A 2,5 @ 600A 1,42 @ 1000A Add 2% for crest factor larger than 2 |
AC current: iFlex probe |
Range |
2500A |
Resolution |
1A (≤2500A), 0,1A (≤999,9 A) |
Accuracy |
3% ± 5 digits (5Hz to 500Hz) |
Crest factor @ 50/60Hz |
3,0 @ 1100A 2,5 @ 1400A 1,42 @ 2500A Add 2% for crest factor larger than 2 |
Position sensitivity |
|
Distance from optimum |
i2500-10 Flex |
i2500-18 flex |
Error |
A |
12,7mm |
35,6mm |
±0,5% |
B |
20,3mm |
50,8mm |
±1,0% |
C |
35,6mm |
63,5mm |
±2,0% |
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. |
DC current measurement |
Range |
999,9A |
Resolution |
0,1A |
Accuracy |
2% ± 5 digits (When using the ZERO function to compensate for offsets) |
AC voltage using FieldSense |
Range |
1000V |
Resolution |
1V (≤1000V) |
Accuracy |
≤4/0 AWG |
3% ± 5 digits (45 to 66Hz) |
≥4/0 AWG |
5% ± 5 digits (45 to 66Hz) |
Wire positioning |
|
Measuring AC voltage via test leads |
Range |
600,0V or 1000V |
Resolution |
0,1V (600,0V range) 1V (1000V range) |
Accuracy |
1% ± 5 digits (20Hz to 500Hz) |
DC voltage |
Ranges |
600,0V or 1000V |
Resolution |
0,1V (600,0V range) 1V (1000V range) |
Accuracy |
1% ± 5 digits |
mV DC measurement |
Range |
500,0mV |
Resolution |
0,1mV |
Accuracy |
1% ± 5 digits |
Measuring frequency via jaw |
Ranges |
5,0 to 500,0Hz |
Resolution |
0,1Hz |
Accuracy |
0,5% ± 5 digits |
Trigger level |
5Hz to 10Hz, ≥10A 10Hz to 100Hz, ≥5A 100Hz to 500Hz, ≥10A |
Measuring frenquecy via iFlex |
Ranges |
5,0 to 500,0Hz |
Resolution |
0,1Hz |
Accuracy |
0,5% ± 5 digits |
Trigger level |
5Hz to 10Hz, ≥25A 10Hz to 100Hz, ≥20A 100Hz to 500Hz, ≥25A |
Resistance |
RRanges |
60.00kΩ 6000Ω 600.0Ω |
Resolution |
0.1Ω (≤600.0Ω) 1Ω (≤6000Ω) 10Ω (≤60.00kΩ) |
Accuracy |
1% ± 5 digits |
Capacitance |
Range |
1000μF |
Resolution |
0.1μF (≤100.0μF) 1μF (≤1000μF) |
Accuracy |
1% ± 4 digits |
Mechanical |
Dimensions |
274 x 86 x 47mm |
Weight |
463g |
Jaw opening |
34mm |
iFlex diameter |
7,5mm |
iFlex cable length |
1,8m (from body to connectors) |
Rogowski coil length |
450mm |
Environmental |
Operating temperature |
-10 to +50°C |
Storage temperature |
-40 to +60°C |
Operating humidity |
Non condensing (<10 °C) ≤90% RH (10 to 30°C) ≤75% RH (30 to 40°C) ≤45% RH (40 to 50°C) |
Temperature coefficients |
Add 0,1x specified accuracy for each degree over 28°C or below 18°C. |
Ingress protection |
IEC 60529: IP30 (closed jaws) |
Operating altitude |
2000m |
Storage altitude |
12 000m |
EMC |
IEC 61326-1: Portable electromagnetic environment IEC 61326-2-2, CISPR 11: Group 1, Class B |
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. |
Safety |
General |
IEC 61010-1: Pollution degree 2 |
Measurement |
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V |
Current clamp for leakage current measurements |
IEC 61557-13: Class 2, ≤30 A/m |
Wireless radio (FC only) |
Certification |
FCC ID: T68-FBLE IC:6627A-FBLE |
Frequency range |
2405 MHz to 2480 MHz |
Output power |
<100 mW |
Radio frequency data |
Radio Frequency Data For Class A Devices. SIMPLIFIED EU DECLARATION OF CONFORMITY: Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. The full text of the EU declaration is available at the following internet address: https://dam-assets.fluke.com/s3fs-public/FLK_RED_1aeng0900.pdf. |