Model |
PicoScope 4224A |
PicoScope 4424A |
PicoScope 4824A |
Oscilloscope - vertical |
Number of input channels |
2 channels |
4 channels |
8 channels |
Bandwidth (-3dB) |
20 MHz (50 mV to 50 V ranges) 10 MHz (10 mV and 20 mV ranges) |
Rise time (cakculated) |
17.5 ns (50 mV to 50 V ranges) 35.0 ns (10 mV and 20 mV ranges) |
Input type |
BNC, at least 20mm spacing |
Vertical resolution |
12 bits |
Software-enhanced vertical resolution |
Up to 16 bits |
Input sensitivity |
2mV/div to 10V/div (10 vertical divisions) |
Input ranges |
±10 mV to ±50 V full scale, in 12 ranges |
Input coupling |
Software-selectable AC / DC |
Input charasteristics |
1 MΩ ∥ 19 pF |
DC accuracy |
±1% of full scale ±300 μV |
Analog offset range (vertical position adjustment) |
±250 mV (10 mV to 500 mV ranges) ±2.5 V (1 V to 5 V ranges) ±25 V (10 V to 50 V ranges) |
Analog offset accuracy |
±1% of offset setting additional to basic DC accuracy |
Maximum input voltage |
±50 V DC, 42.4 V peak AC |
Overvoltage protection |
±100 V (DC + AC peak) |
Oscilloscope - horizontal |
Maximum sampling rate (real-time) |
80 MS/s (up to four channels in use) 40 MS/s (five or more channels in use) |
Maximum sampling rate (USB 3.0, continuous streaming mode) |
20 MS/s using PicoScope 6 software, shared between channels 80 MS/s max. for a single channel using PicoSDK. 160 MS/s total across all channels. (PC-dependent) |
Timebase ranges |
20 ns/div to 5000 s/div |
Buffer memory |
256 MS shared between active channels |
Streaming buffer memory (PicoScope) |
100 MS |
Streaming buffer memory (SDK) |
Up to available PC memory |
Maximum buffer segments |
10 000 |
Maximum waveforms per second |
100 000 (PC-dependent) |
Timebase accuracy |
±20 ppm (+5 ppm/year) |
Sample jitter |
25 ps RMS typical |
Dynamic performance (typical) |
Crosstalk |
−76 dB, DC to 20 MHz |
Harmonic distortion |
< −60 dB, 10 mV range < −70 dB, 20 mV and higher ranges |
SFDR |
> 60 dB, 20 mV and 10 mV ranges > 70 dB, 50 mV and higher ranges |
Noise |
45 μV RMS on 10 mV range |
Bandwidth flatness |
DC to full bandwidth (+0.2 dB, −3 dB) |
Pulse response |
< 1% overshoot |
Triggering |
Source |
Channels A to B |
Channels A to D |
Channels A to H |
Trigger modes |
Free run, auto, repeat, single, rapid (segmented memory) |
Trigger types |
Edge with adjustable hysteresis, pulse width, window, window pulse width, dropout, window dropout, interval, logic level, runt pulse |
Trigger sensitivity |
Digital triggering provides 1 LSB accuracy up to full bandwidth |
Maximum pre-trigger capture |
100% of capture size |
Maximum post-trigger delay |
Zero to 4 billion samples (settable in 1 sample steps) |
Trigger rearm time |
< 3 μs on fastest timebase |
Maximum trigger rate |
Up to 10 000 waveforms in a 30 ms burst |
Advanced digital trigger levels |
All trigger levels, window levels and hysteresis values settable with 1 LSB resolution across input range |
Advanced digital time intervals |
Settable with 1 sample resolution from 1 sample (minimum 12.5 ns) up to 4 billion sample intervals |
Function generator |
Standard output signals |
Sine, square, triangle, DC voltage, ramp, sinc, Gaussian, half-sine, white noise, PRBS |
Standard signal frequency |
0.03 Hz to 1 MHz |
Sweep modes |
Up, down, dual |
Triggering |
Can trigger a counted number of waveform cycles or sweeps (up to 1 billion) from the scope trigger or manually from software. |
Frequency accuracy |
±20 ppm |
Frequency resolution |
< 0.02 Hz |
Voltage range |
±2 V |
Amplitude and offset adjustment |
Signal amplitude and offset within ± 2V range. Adjustable in approx 300 μV steps. |
Amplitude flatness |
< 0.5 dB to 1 MHz typical |
DC accuracy |
±1% of full scale |
SFDR |
87 dB typical |
Output characteristics |
Rear-panel BNC, 600 Ω output impedance |
Overvoltage protection |
±10 V |
Arbitrary Waveform Generator |
Update rate |
80 MS/s |
Buffer size |
16 kS |
Resolution |
14 bits (output step size approximately 300 μV) |
Bandwidth |
1 MHz |
Rise time (10% to 90%) |
150 ns |
Sweep modes, triggering, frequency accuracy and resolution, voltage range and accuracy and output characteristics as for function generator. |
Spectrum analyzer |
Frequency range |
DC to 20 MHz |
Display modes |
Magnitude, average, peak hold |
Windowing functions |
Rectangular, Gaussian, triangular, Blackman, Blackman-Harris, Hamming, Hann, flat-top |
Number of FFT points |
Selectable from 128 up to 1 million in powers of 2 |
Scale / units |
X axis : linear or log 10 Y axis : logarithmic (dbV, dBu, dBm, arbitrary) or linear (volts) |
Math channels |
General functions |
−x, x+y, x−y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan, arcsin, arccos, arctan, sinh, cosh, tanh, derivative, integral, delay |
Filter functions |
Lowpass, highpass, bandstop, bandpass |
Graphing functions |
Frequency, duty cycle |
Multi-waveform functions |
Min, max, average, peak |
Operands |
Input channels, reference waveforms, time, constants, pi |
Automatic measurements |
Scope mode |
AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak to peak, rise time, rising rate. |
Spectrum mode |
Frequency at peak, amplitude at peak, average amplitude at peak, total power, THD %, THD dB, THD+N, SFDR, SINAD, SNR, IMD |
Statistics |
Minimum, maximum, average and standard deviation |
DeepMeasure™ |
Scope mode |
AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak to peak, rise time, rising rate. |
Spectrum mode |
Frequency at peak, amplitude at peak, average amplitude at peak, total power, THD %, THD dB, THD+N, SFDR, SINAD, SNR, IMD |
Statistics |
Minimum, maximum, average and standard deviation |
Serial decoding |
Protocols |
1-Wire, ARINC 429, CAN, CAN FD, DALI, DCC, DMX512, Ethernet (10Base-T), FlexRay, I²C, I²S, LIN, Manchester, MODBUS (ASCII and RTU), PS/2, SENT, SPI, UART/RS-232. Subject to number of channels available. |
Inputs |
All input channels with any mixture of protocols |
Mask limit testing |
Mask creation |
User-drawn, table entry, auto-generated from waveform or imported from file |
Actions |
Highlight on screen, select in buffer overview, activate alarm |
Statistics |
Pass/fail, failure count, total count |
Alarms |
Initiating events |
Capture, buffer full, mask fail |
Alarm actions |
Beep, play sound, stop/restart capture, run executable, save current buffer/all buffers, trigger signal generator |
Display |
Interpolation |
Linear or sin(x)/x |
Persistence modes |
Digital color, analog intensity, fast, custom |
Data export |
Output file formats |
BMP, CSV, GIF, JPG, MATLAB 4, PDF, PNG, PicoScope data, PicoScope settings, TXT |
Output functions |
Copy to clipboard, print |
Environmental |
Temperature range (operating) |
0 °C to 45 °C |
Temperature range (stated accuracy) |
20 °C to 30 °C |
Temperature range (storage) |
–20 °C to +60 °C |
Humidity range (operating) |
5% to 80% RH non-condensing |
Humidity range (storage) |
5% to 95% RH non-condensing |
Altitude |
Up to 2000 m |
Pollution degree |
EN 61010 pollution degree 2: “only nonconductive pollution occurs except that occasionally a temporary conductivity caused by condensation is expected” |
Physical properties |
Dimensions |
190 x 170 x 40 mm |
Weight |
< 0.55 kg |
Software |
Windows software |
PicoScope 6 PicoLog 6 PicoSDK software development kit Windows 7, 8 or 10 recommended |
macOS software |
PicoScope 6 Beta (feature list) PicoLog 6 Software development kit (SDK) OS versions: see release notes |
Linux software |
PicoScope 6 Beta (feature list) Software development kit (SDK) See Linux Sofware and Drivers for details of supported distributions |
Raspberry Pi software |
PicoLog 6 for Raspberry Pi 3B and 4B (Raspberry Pi OS) |
Languages |
PicoScope 6: English, Chinese (simplified), Chinese (traditional), Czech, Danish, Dutch, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish PicoLog 6: English (UK), English (US), Simplified Chinese, Dutch, French, German, Italian, Japanese, Korean, Russian, Spanish |
General |
What's in the box? |
PicoScope 4000A Series high-resolution oscilloscope USB 3.0 cable USB Oscilloscope Quick Start Guide 10:1/1:1 switched probes (quantity shown below) |
Number of probes included |
2 |
4 |
4 |
PC connectivity |
SuperSpeed USB 3.0 (USB 2.0 compatible) |
Power requirements |
Powered from USB |
Ground terminal |
M4 screw on rear panel |
Safety compliance |
Designed to EN 61010-1; LVD compliant |
EMC compliance |
Tested to meet EN61326-1 and FCC Part 15 Subpart B |
Environmental compliance |
RoHS and WEEE |
Warranty |
5 years |