Fluke Bm. 232D - Electrical Safety Analyzer

Fluke Bm. 232D - Electrical Safety Analyzer

The 232D Electrical Safety Analyzer is a versatile, full-featured manual tester that combines both safety testing and ECG simulation in one portable package.
The test receptacle on the top panel simulates the standard single-fault conditions to assist technicians in assessing equipment safety. An internal GFCI protects both the operator and the equipment under test.
The 232D’s robust features simplify analysis of sophisticated equipment, such as 12-lead electrocardiographs or recorders. The device features a wide range of ECG simulations and performance testing waveforms, as well as 10 jacks for patient applied parts testing. The 232D conducts leakage current tests on all or individual patient electrodes and between specified patient electrode pairs.

More details

Dostupnosť: Na objednávku
 
Informácie
  • ECG-performance testing
  • 12-lead ECG simulation and patient applied parts testing
  • GFCI protection
  • 115 V and 15 A operation
  • Easy-to-use
  • Portable
  • Rugged design
232D Electrical Safety Analyzer
Specifications
Display
Autoranging 3.5 digit, red LED
Overrange indicated by a flashing "1999" reading
Ambient Temperature
Operating:15 °C to 35 °C (59 °F to 95 °F)
Storage:0 °C to 50 °C (32 F° to 122 °F)
LED Indicators
Resistance current source active
Test receptacle GFCI tripped
ECG-performance tests active
Input Jacks
Meter inputs:4.2 mm/0.166"-diameter banana jacks
Electrical-Safety Tests
Resistance
Test lead (one Kelvin cable required)
Point-to-point environmental test (two Kelvin cables required)
Accuracy:± (2 % of reading +2 counts)
Range:0 mΩ to 5000 mΩ
Leakage Current
Case leakage current (with external cable)
Case leakage current (via power cord ground conductor)
All ECG leads (single leads RL, RA, LA, LL & V1-V6, interleads RA-RL, LA-RL, and LA-RA and patient lead isolation; all leads @ line voltage / 1 mA)
Accuracy:± (5 % of reading + 1 uA) @ DC and from 48 Hz to 100 kHz
Load Current
Range:Current draw by device 0.1 A to 15 A
Accuracy:± 5% of range
True RMS Voltage
Measurement of L1-G, L2-G, and L1-L2 (line voltage)
Voltage gradient (mV)
0 mV to 199.9 mV (autoranging)
0 mV to 1999 mV (autoranging)
0 V to 199.9 V
Accuracy:± (2 % of reading + 2 counts) to 100 Hz
Test-Load Impedance
ANSI/AAMI ES1-1993 (revision of the earlier ANSI/AAMI ES1-1985 and SCL-12/78)
1000 Ω ± 1 % @ DC
ECG Jacks
Ten AHA color-coded universal binding posts, compatible with 3.2 mm and 4.0 mm pins and disposable snap electrodes
Power Requirements
Available only in 115-V, @ 15 A, 50 / 60 Hz
Detachable hospital-grade power cord (supplied)
Internal instrument power usage of < 100 mA
Test Receptacle
Standard U.S. 115-V/15-A, hospital grade ONLY
Front panel switches for selecting power ON/OFF to the equipment under test, normal/reverse polarity, open/closed ground, open/closed neutral
ECG-Performance Testing (Lead I)
Square Wave:2 Hz, 1 mV bipolar
DC Pulse:4 seconds, +1 mV
Sine Waves:10 Hz, 40 Hz, 60 Hz, 100 Hz, 1 mV p-p
Triangle Wave:2 Hz, 3 mV p-p
ECG normal sinus rhythm:30 BPM, 60 BPM, 120 BPM, 180 BPM and 240 BPM (± 0.5 %), 1 mV
Other Functions
Ground fault circuit interrupter (GFCI) to protect operator unit under test (by detecting a test-receptacle fault of > 10 mA ± 10 %)
Dimensions (WxDxH)
(22.86 cm x 22.86 cm x 10.16 cm )
9 in x 9 in x 4 in
Weight (without accessories)
2.32 kg (5.1 lb)