PT-100 Fluke 5699 - Inconel™ SPRT sonda –200°C až 670°C 1656430 Range to aluminum point (660°C ) Inconel™ and platinum sheaths guard against contamination Drifts less than 10 mK/year with normal use Many calibration options available including by fixed point Fifth wire provides shield ground Ask for quotation
PT-100 Fluke 5698 - referenčná SPRT sonda –200°C až 670°C 1884947 Conforms to ITS-90 SPRT guidelines Drift rate typically 0.003 °C Calibration options by fixed point Unmatched performance-to-price-ratio Ask for quotation
PT-100 Fluke 5686 - sklenená SPRT sonda –260°C až 500°C 1656362 Temperatures from –260°C (13K) to 500°C Stability typically 0.001°C over 100°C range Miniature capsule package eliminates stem conduction Ask for quotation
PT-100 Fluke 5685 - referenčná SPRT sonda 0°C až 1070°C 1656355 Drift rates as low as 0.0005 K Proprietary gas mixture ensures high stability Most experienced SPRT design team in the business Ask for quotation
PT-100 Fluke 5684 - referenčná SPRT sonda 0°C až 1070°C 1656343 Drift rates as low as 0.0005 K Proprietary gas mixture ensures high stability Most experienced SPRT design team in the business Ask for quotation
PT-100 Fluke 5683 - referenčná SPRT sonda –200°C až 480°C 1656337 Drift rates as low as 0.0005 K Proprietary gas mixture ensures high stability Most experienced SPRT design team in the business Ask for quotation
PT-100 Fluke 5681 - referenčná SPRT sonda –200°C až 670°C 1656319 Drift rates as low as 0.0005 K Proprietary gas mixture ensures high stability Most experienced SPRT design team in the business Ask for quotation
PT-100 Fluke 5628 - sekundárna PRT 3055543 Range to 660°C Meets all ITS-90 reMeets all ITS-90 requirements for resistance ratios Rtp drift < 20mK after 500 hours at 660°C Strain-free sensor design by Hart’s SPRT engineers Ask for quotation
PT-100 Fluke 5626 - sekundárna PRT 3055440 Range to 660°C Meets all ITS-90 reMeets all ITS-90 requirements for resistance ratios Rtp drift < 20mK after 500 hours at 660°C Strain-free sensor design by Hart’s SPRT engineers Ask for quotation
PT-100 Fluke 5624 - PRT do 1000°C 4284327 Temperature range of 0°C to 1000°C Accuracy (includes short-term stability and calibration uncertainty) of ±0.05°C to 962°C Long-term drift of 0.01°C at 0°C after 100 hours at 1000°C Designed by Hart’s primary standards design team Ask for quotation
PT-100 Fluke 5622 - platinová sonda s rýchlou odozvou (PT100) 1653385 Odporové platinove teplotné sondy s rýchlou odozvou. Použiteľné ako DIN/IEC trieda "A" PRT alebo s kalibráciou podľa ITS-90. Priemer sondy od 0,5 po 3,2 mm. Ask for quotation
PT-100 Fluke 5618 - industriálna RTD 3003322 Small diameter sheath, 3.2mm (0.125 in) Excellent stability Includes ITS-90 coefficients NVLAP-accredited calibrated from –200°C to 500°C Ask for quotation
PT-100 Fluke 5615 - sekundárna PRT sonda, 100 Ohm 3055386 Affordable wide-range accuracy Excellent stability Reference-grade platinum sensing element NVLAP accredited calibration included Ask for quotation
PT-100 Fluke 5608 - sekundárna PRT –200°C až 500°C 4352001 5608: –200 °C to 500 °C (80 mm minimum immersion) 5609: –200 °C to 670 °C (100 mm minimum immersion) ± 0.01 short-term stability Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0 Dry-well reference with 90 ° bend Ask for quotation