PT-100 Fluke 5686B - Glass capsule SPRT (–260°C to 500°C) 1656362 Temperatures from –260°C (13K) to 500°C Stability typically 0.001°C over 100°C range Miniature capsule package eliminates stem conduction Vyžiadajte si ponuku
PT-100 Hart Scientific 5685 - Standard Platinum Resistance... 1656355 Drift rates as low as 0.0005 K Proprietary gas mixture ensures high stability Most experienced SPRT design team in the business Vyžiadajte si ponuku
PT-100 Hart Scientific 5684 - Standard Platinum Resistance... 1656343 Drift rates as low as 0.0005 K Proprietary gas mixture ensures high stability Most experienced SPRT design team in the business Vyžiadajte si ponuku
PT-100 Hart Scientific 5683 - Standard Platinum Resistance... 1656337 Drift rates as low as 0.0005 K Proprietary gas mixture ensures high stability Most experienced SPRT design team in the business Vyžiadajte si ponuku
PT-100 Hart Scientific 5681 - Etalónový platinový odporový... 1656319 Drift rates as low as 0.0005 K Proprietary gas mixture ensures high stability Most experienced SPRT design team in the business Vyžiadajte si ponuku
Termistory Hart Scientific 5665 - Secondary Reference Thermistor... 1655698 Short-term accuracy to ± 0.01 °C; one-year drift < ± 0.01 °C Accredited NVLAP calibration optional Flexible Teflon and silicone coated fast-response models Rugged polished stainless steel sheaths Vyžiadajte si ponuku
Teplota a vlhkosť Hart Scientific 5650 - Type S Thermocouple Standards... 1655543 Designed by Hart’s primary standards design team Two sizes available, with or without reference junction Uncalibrated accuracy is the greater of ±0.6°C or ±0.1% of reading† Individual fixed-point calibration available Vyžiadajte si ponuku
Termočlánky Hart Scientific 5649 - Type R Thermocouple Standards (0°C... 2085857 Designed by Hart’s primary standards design team Two sizes available, with or without reference junction Uncalibrated accuracy is the greater of ±0.6°C or ±0.1% of reading† Individual fixed-point calibration available Vyžiadajte si ponuku
Termistory Hart Scientific 5644 - Standards Thermistor Probe 1655478 Accuracy to ± 0.001 °C Affordable system accuracy to ± 0.004 °C or better NIST-traceable calibration included from manufacturer; accredited Hart calibration optional Vyžiadajte si ponuku
Termistory Hart Scientific 5643 - Standards Thermistor Probe 1655386 Accuracy to ± 0.001 °C Affordable system accuracy to ± 0.004 °C or better NIST-traceable calibration included from manufacturer; accredited Hart calibration optional Vyžiadajte si ponuku
Termistory Hart Scientific 5642 - Standards Thermistor Probe 1655200 Accuracy to ± 0.001 °C Affordable system accuracy to ± 0.004 °C or better NIST-traceable calibration included from manufacturer; accredited Hart calibration optional Vyžiadajte si ponuku
Termistory Hart Scientific 5641 - Standards Thermistor Probe 1655013 Accuracy to ± 0.001 °C Affordable system accuracy to ± 0.004 °C or better NIST-traceable calibration included from manufacturer; accredited Hart calibration optional Vyžiadajte si ponuku
Termistory Hart Scientific 5640 - Standards Thermistor Probe 1654822 Accuracy to ± 0.001 °C Affordable system accuracy to ± 0.004 °C or better NIST-traceable calibration included from manufacturer; accredited Hart calibration optional Vyžiadajte si ponuku
RTD Hart Scientific 5627 - Probe (–200°C to 420°C) 3055519 Vibration and shock resistant 3/4-inch bend radius for increased durability NVLAP-accredited calibration included Vyžiadajte si ponuku
PT-100 Hart Scientific 5628 - Secondary Standard Platinum... 3055543 Range to 660°C Meets all ITS-90 reMeets all ITS-90 requirements for resistance ratios Rtp drift < 20mK after 500 hours at 660°C Strain-free sensor design by Hart’s SPRT engineers Vyžiadajte si ponuku
PT-100 Hart Scientific 5626 - Etalónový platinový odporový teplomer 3055440 Range to 660°C Meets all ITS-90 reMeets all ITS-90 requirements for resistance ratios Rtp drift < 20mK after 500 hours at 660°C Strain-free sensor design by Hart’s SPRT engineers Vyžiadajte si ponuku
PT-100 Hart Scientific 5624 - Platinum Resistance Thermometer to... 4284327 Temperature range of 0°C to 1000°C Accuracy (includes short-term stability and calibration uncertainty) of ±0.05°C to 962°C Long-term drift of 0.01°C at 0°C after 100 hours at 1000°C Designed by Hart’s primary standards design team Vyžiadajte si ponuku
RTD Hart Scientific 5623 - Precision RTD Freezer Probe 3003488 Fully immersible probe assembly to –100°C NVLAP-accredited calibration and ITS-90 coefficients included Accuracy to ±0.05°C over the full range Vyžiadajte si ponuku