AC/DC Klieštový multimeter
Fluke 317/319 Clamp Meters
General Specifications |
Digital Display |
|
Low Battery Indication |
|
Power Supply |
|
3 x AAA IEC LR03 batteries |
|
Clamp Opening Size |
|
Jaw Diameter |
|
Dimensions (L x W x H) |
|
234 x 74 x 34.8 mm |
|
6.39 in x 2.29 in x 1.20 in |
|
Weight |
|
384g (including batteries) |
|
Automated measurement |
|
Safety |
|
CE |
|
EN/IEC 61010-1 and IEC 61010-2-032 |
|
Installation type III, 600V working environment |
|
317 Electrical Specifications |
Current AC |
Range |
40.00 A, 600.0 A |
Resolution |
0.01 A, 0.1 A |
Accuracy |
1.6% ± 6 digit (50-60 Hz) {40 A} |
|
2.5% ± 8 digit (60-500 Hz) {40 A} |
|
1.5% ± 5 digit (50-60 Hz) {600 A} |
|
2.5% ± 5 digit (60-500 Hz) {600 A} |
Crest Factor add 2% into spec for CF > 2 |
3.0 Max @ 500 A, 2.5 Max @ 600 A |
AC response |
rms |
|
Current DC |
Range |
40.00 A, 600.0 A |
Resolution |
0.01 A, 0.1 A |
Accuracy |
1.6% ± 6 digit (40 A) |
|
1.5% ± 5 digit (600 A) |
|
Voltage AC |
Range |
600.0 V |
Resolution |
0.1 V |
Accuracy |
1.5% ± 5 digit (20-500Hz) |
AC response |
rms |
|
Voltage DC |
Range |
600.0 V |
Resolution |
0.1 V |
Accuracy |
1% ± 4 digit |
|
Resistance |
Range |
400.0 Ω, 4000 Ω |
Resolution |
0.1 Ω, 1 Ω |
Accuracy |
1% ± 5 digit |
|
Continuity (Ω) |
|
Inrush |
|
Frequency (HZ) |
Range |
N/A |
Accuracy |
N/A |
Trigger Level |
N/A |
|
319 Electrical Specifications |
Current AC |
Range |
40.00 A, 600.0 A, 1000 A |
Resolution |
0.01 A, 0.1 A, 1 A |
Accuracy |
1.6% ± 6 digit (50-60 Hz) {40 A} |
|
2.5% ± 8 digit (60-500 Hz) {40 A} |
|
1.5% ± 5 digit (50-60 Hz) {600/1000 A} |
|
2.5% ± 5 digit (60-500 Hz) {600/1000 A} |
Crest Factor add 2% into spec for CF > 2 |
3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A |
AC response |
rms |
|
Current DC |
Range |
40.00 A, 600.0 A, 1000 A |
Resolution |
0.01 A, 0.1 A, 1 A |
Accuracy |
1.6% ± 6 digit (40 A) |
|
1.5% ± 5 digit (600/1000 A) |
|
Voltage AC |
Range |
600.0 V |
Resolution |
0.1 V |
Accuracy |
1.5% ± 5 digit (20-500Hz) |
AC response |
rms |
|
Voltage DC |
Range |
600.0 V |
Resolution |
0.1 V |
Accuracy |
1% ± 4 digit |
|
Resistance |
Range |
400.0 Ω |
|
4000 Ω |
Resolution |
0.1 Ω |
|
1 Ω |
Accuracy |
1% ± 5 digit |
|
Continuity (Ω) |
|
Inrush |
|
Frequency (HZ) |
Range |
5.0 - 500.0 Hz |
Accuracy |
0.5% ± 5 digit |
Trigger Level |
10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A |
|
All precisions refer to 73 °F ± 41 °F (23 °C ± 5 °C).
Less than 64 °F and greater than 82 °F (18 °C and greater than 28 °C)
Environmental Specifications |
Operating Temperature |
|
14°F to 122°F (-10 °C to 50 °C) |
|
Storage Temperature |
|
-40 °F to 140 °F (-40 °C to 60 °C) |
|
Operating Humidity |
|
Non condensing (< 50 °F) (< 10 °C) |
|
90 % RH (50 °F to 86 °F) (10 °C to 30 °C) |
|
75 % RH (86 °F to 104 °F) (30 °C to 40 °C) |
|
45 % RH (104 °F to 122 °F) (40 °C to 50 °C) |
|
Non-condensing |
|
Operating Altitude |
|
Storage Altitude |
|
IP Rating |
|
Vibration Requirements |
|
Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis |
|
Drop Test Requirements |
|
EMI, RFI, EMC |
|
Without special EMC environmental usage ≥ 0.1 V/m |
|
Temperature Coefficients |
|
0.1x (stipulated precision)/ °C |
|
(<64 °F or > 82° F) |
|
(<18 °C or > 28 °C) |
|