Fluke Calibration 909 - Frequency References

Stable frequency references fortest systems and calibration labs

The 908 and 909 are ideal for use in calibration laboratories where there is a specific need to calibrate a wide range of instruments, such as frequency counters and synthesizers. Unlike off-air frequency receivers, the 908 and 909 have excellent short-term stability that enables much faster frequency calibration.
If frequency standards are located in several departments, spread over a number of buildings, you will discover the portable 909 Rubidium standard offers a more cost-effective solution than a central reference with a costly distribution system.

Dostupnosť Opýtajte sa
Možnosti doručenia
Kód: 1583692
€18 415,20 €15 346 bez DPH
Fluke Calibration 909 - Frequency References
Fluke Calibration 909 - Frequency References
Cena na požiadanie
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.
  • Accurate reference "Atomic clock" in automated test systems
  • Affordable and very cost effective
  • Designed for portability with optional carrying case
  • No need for battery backup during transportation
  • Fast warm-up time
908/909 Frequency References
Stable frequency references for test systems and calibration labs

The 908 and 909 Frequency Standards are designed for use as accurate reference clocks in automated test systems and as in-house frequency standards.

Because they require only a short warm-up time to reach specified stability, they can also be used as portable frequency standards.

The 909 includes an ultra-stable Rubidium timebase ("atomic clock"), while the 908 is built around a high-stability oven-controlled cut crystal oscillator. Both instruments provide five buffered 10 MHz outputs plus one 5 MHz output. Option 70 increases the number of 10 MHz outputs to ten.

Ideal for automated test (ATE) systems

Many production test systems, particularly in the telecommunications industry, require a stable external frequency clock as a reference. Depending on your needs either the 908 or the 909 can supply a stable frequency reference to up to 11 other instruments and testers, making them ideal for use in an ATE system. In addition there is a rack mounting kit available.

908 (Crystal oven)

With its high-stability oven-controlled SC-cut crystal oscillator the 908 offers the lowest purchase cost per output on the market in the 11 output version (option 70 installed).

909 (Rubidium)

The Rubidium version, with its negligible aging drift needs in practice no adjustment during the lifetime of the test system.

In-house frequency standards

Both the 908 and the 909 are ideal for use in calibration laboratories where there is a need to calibrate a wide range of instruments, such as frequency counters and synthesizers. Unlike off-air frequency receivers, the 908 and 909 have very-high short-term stability that enables much faster frequency calibration.

Companies that require frequency standards in numerous departments spread over several buildings will find that a local Rubidium standard (909) normally offers a more cost effective solution than a central reference with a costly distribution system.

Made for portability

The 908 and 909 are designed for portability. They perform exceptionally well as transportable fast-warm-up frequency references. Traditionally, oven oscillators using AT-cut crystal could not maintain their specification without continuous battery backup during transportation to different sites. This is because AT-cut crystals suffer from significant frequency retrace (frequency offset after a power interruption). They also need a very long warm-up time, 24 hours or more, to arrive at the final frequency value.

The 908"s oven oscillator is designed around the more advanced SC-cut crystal oscillator which has virtually no retrace. In just 10 minutes the frequency is within 5x10-9 of the final value, meaning it can be in service faster. Finally, there is no need for battery back up during transportation. The warm-up of the Model Rubidium oscillator is even faster, taking only 10 minutes to reach as close as 4x10-10 from the final frequency.

For protection during transport and storage, there is a carrying case available. The 908 and 909 provide stabile, cost effective solutions for your frequency reference requirements whether in ATE, laboratory or portable applications.

Calibration Instruments   >   All Calibration Instruments   >  
908/909 Frequency References
Reference outputs
Base model
5x10 MHz, 1x5 MHz: sine > 0.6V rms in 50Ω
With Option 70
10 x 10 MHz, 1 x 5 MHz: sine > 0.6V rms in 50Ω

Frequency Stability
Aging per month
908 (Oven): 3x10 -9
909 (Rubidium): 5x10 -11
Aging per year (per 10 years)
908 (Oven): 2x10 -8 (1 year)
909 (Rubidium): 1x10 -9 (10 years)
Temperature
(20°C to 26°C)
908 (Oven): 4x10 -10 typ.
909 (Rubidium): 2x10 -11 typ.
--------
(0°C to +50°C)
908 (Oven): 2.5x10 -9
909 (Rubidium): 3x10- -10
Short term (root Allan variance)
908 (Oven): 5x10 -12 , t= 10s
909 (Rubidium): 1x10 -11 , t=10s
--------
908 (Oven): 5x10 -12 , t=1s
909 (Rubidium): 3x10 -11 , t=1s
Warm up (at +25oC)
908 (Oven): 10 mins. to 5x10 -9
909 (Rubidium): 5.4 mins. to lock
11 mins. to 4x10 -10

Environment
Temperature
0°C to +50°C (operating)
-40°C to +70°C (storage)
Safety
Compliant to EN 61010-1 and CE
EMI
Compliant to EN 55011 ISM group, class B, EN 50082-2 and CE

Power Consumption (90-264V, 47-63 Hz)
908:
<20W at warm up, < 7W continuous operation
909:
<70W at warm up, <30W continuous operation

Dimensions and Weight
Size
315 x 86 x 395 mm
(12.4 x 3.4 x 15.5 ins)
Weight
4.8 kg (net), 7.8 kg (shipping)
(10.6 lb (net), 18.2 lb (shipping))

Buďte prvý, kto napíše príspevok k tejto položke.