TTi PL330QMD - Presný laboratórny zdroj s lineárnou reguláciou 32V/3.1A (190W)

65W to 240W, Linear, Single, Dual & Triple Output

  "Industry Standard" laboratory PSU range
  32V/3A Dual ; LED displays
  Wide model range, single, dual or triple outputs
  Separate digital meters for voltage and current
  Twin 3¾ digit meters with 12.5mm LEDs 
  0.1% accuracy, 10mV and 1mA resolution
  Parallel, series and tracking modes on duals/triples
  High current 5V logic output on triples



Dostupnosť Na objednávku
Môžeme doručiť do:
16.8.2024
Možnosti doručenia
Kód: 924
€1 €0,83 bez DPH
TTi PL330QMD - Presný laboratórny zdroj s lineárnou reguláciou 32V/3.1A (190W)
TTi PL330QMD - Presný laboratórny zdroj s lineárnou reguláciou 32V/3.1A (190W)
Ukončená výroba
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

OVERVIEW

The Thurlby Thandar PL series of laboratory bench power supplies has established itself in many countries as an “industry standard” range.

Digital accuracy and convenience
PL series units incorporate digital meters with a 3.75 digit scale length (4095 counts) to provide greater accuracy and resolution than other PSUs.
Large and bright LEDs give a clear and unambiguous reading. An update rate of 4 per second provides near instantaneous response.
Separate meters are used for voltage and current, eliminating the need for meter function switches with their attendant problems of misinterpretation.
A damping switch for the current meter simplifies measurements on rapidly varying loads.

Remote sense for precision at high currents
Remote sense terminals enable the precision to be maintained at high currents by eliminating the effects of connection lead resistance.
Without remote sense lead resistance of just a few tens of milliohms can seriously degrade regulation and produce misleading results. (Two cables of 0.05W each will drop a total of 0.3V at 3 Amps.)

Safety and protection
PL series PSUs are designed and built to meet the stringent requirements of IEC348 and IEC1010.
All outputs are fully protected against short circuit, reverse voltage and reverse currents.

 

Greater resolution and control
The PL series sets the standard for simple and comprehensive control. Voltages are set with coarse and fine controls for speed with precision. Currents are set with a semi-logarithmic control for increased resolution at low current levels.
The DC output switch enables voltage and current levels to be set before the load is connected. With the output switch “off” the the current limit set point is displayed. With the output switch “on” the actual output current flowing is displayed.
This invaluable feature allows delicate circuits to be protected by accurately setting the current limit level (down to a few milliamps if necessary) before connecting the circuit under test.

Quad-mode duals and triples

The  32V-2A and 32V-3A supplies are each available as a dual unit incorporating push button selection of four modes of operation:

Isolated - 2 x single outputs

True Parallel - The Master acts as a single supply of twice the current capability.

Series - Outputs connected in series but with independent control.

Series Tracking - As series but both voltages are set with the Master voltage control.

Each of the quad-mode dual models is alternatively available as a triple supply incorporating one further independent output. This is a higher current 5 Volt output intended for powering logic circuits. 


MAIN OUTPUT(S)
Output Range 0 - 32 Volts nominal; 0 - 15.5V (PL154).
0 - 2.1A (PL320); 0 - 3.1A (PL330); 0 - 4A (PL154).
Voltage Setting By coarse and fine controls; resolution <5mV.
Current Setting By single logarithmic control.
Output Mode Constant voltage or constant current modes with automatic cross-over.
Configuration Selection Isolated, True parallel, Series or Series Tracking via front panel switches. (QMD and QMT only)
Output Switch Isolates the output. Permits voltage and current limits to be set up before connecting the load.
Output Terminals 4mm terminals on 19mm (0.75") spacing.
Output Impedance Constant Voltage Typically <5mW at 1kHz.
Constant Current Typically 50kW.
Output Protection Max. output voltage +20 volts forward; diode clamped for reverse, up to 3A reverse current.
Load Regulation <0.01% of max. output for 90% load change
Line Regulation <0.01% of max. output for 10% line change
Remote Sense Remote Sense
Ripple and Noise Typically <1mV rms
Transient Response <20usec to <50mV for 90% load change
Temp. Coefficient Typically <100ppm/°C
Meter Type Dual 4 digit with 12.5mm LEDS, Reading rate 4 per second.
Meter Resolution Voltage 10mV over the entire range, Current 1mA over the entire range
Meter Accuracy Voltage ±(0.1% of reading + 1 digit), Current ±(0.3% of reading + 1 digit)
Current Meter Damping Nominally 20ms, switchable to 2 sec for averaging of rapidly varying loads
LOGIC OUTPUT - PL320QMT & PL330QMT
Output Range 4 to 6 Volts at 0.1 - 4 Amps (7A on PL330QMT).
Output Switch Isolates the output and permits output voltage to be set before connecting the load.
Output Protection Over-voltage protection operates above 7V.Diode clamped for reverse currents up to 3A.
Load Regulation <0.01% of max. output for 90% load change
Line Regulation <0.01% of max. output for 10% line change
Remote Sense Eliminates up to 0.5V drop per lead.
Ripple and Noise Typically <1mV rms
Transient Response <20µsec to <50mV for 90% load change
Temp. Coefficient Typically <100ppm/°C
LOGIC OUTPUT METER - (PL330QMT only)
Meter Type 3 digit with 12.5mm LEDs. Reading rate 4/s. Shows volts with output off, amps with output on.
Meter Resolution Voltage 10mV, Current 10mA
Meter Accuracy Voltage ±(0.2% of reading + 1 digit ), Current ±(0.5% of reading + 1 digit )
GENERAL
Power Requirements 110, 120, 220 or 240VAC 50/60Hz ±10%
Operating Range 5°C to 40°C, 20% to 80% RH
Storage Range -20°C to +60°C
Size Single - 170(H) x 155(W) x 265mm(D), (PL330 - 300D)
Dual - 170(H) x 350(W) x 265mm(D), (PL330QMD - 300D)
Triple - 170(H) x 425(W) x 265mm(D), (PL310QMD - 350W, PL330QMD - 300D)
Weight PL320 & PL154 - 5.0kg, PL330 - 6.0kg, PL320QMD - 9.5kg, PL330QMD - 12.0kg, PL320QMT - 13.5kg, PL330QMT - 15.5kg.
Electrical Safety Designed and manufactured to comply with IEC 348 and IEC1010-1. Full safety sockets available to special order.
EMC Designed and manufactured to comply with EN50081–1 and EN50082–1.