TTi TGP110 - Pulzný generátor s možnosťou oneskorenia 10MHz

TGP110 - 10MHz Pulse Generator with Delay

  0.1Hz to 10MHz frequency range
  Independent control of pulse frequency, width and delay
  50ns minimum pulse width
  Squarewave, double pulse & delayed pulse modes
  Free-run, gated and triggered modes
  50 Ohm output: 0.1V to 10V amplitude
  TTL/CMOS and Sync outputs
  Low-cost

Dostupnosť Na objednávku
Môžeme doručiť do:
16.8.2024
Možnosti doručenia
Kód: 59120-1200
€564,48 €470,40 bez DPH
TTi TGP110 - Pulzný generátor s možnosťou oneskorenia 10MHz
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

An essential instrument
The generation of pulses for the stimulus and control of electronic systems is beyond the capability of all but the most sophisticated of function generators. The architecture of a dedicated pulse generator enables it to generate pulses of a set width regardless of the repetition rate offering duty cycles which can extend down to 1 in 100 million.
In addition to continuous operation, single or multiple pulses can be generated in response to trigger or gating signals with precisely defined timing relationships. A dedicated pulse-waveform output amplifier provides flat top pulses with fast rise and fall times at variable amplitude.

Variable delay
The TGP110 offers selectable delay between the sync output and pulse output. In triggered mode this also sets the delay between a trigger signal and the start of the pulse.

Wide pulse range
The TGP110 can generate pulse widths in the range 50ns to 5s. There are eight overlapping decade ranges with vernier control within each range.
The period range is 100ns to 10s, equivalent to a repetition rate range of 10MHz to 0.1Hz. Delay is independently adjustable over the same range as pulse width. A complement switch inverts the mark-space polarity.

Squarewave and double pulse
In square mode, squarewaves are generated at a frequency set by the period controls alone. This provides a convenient means of generating variable period edges where the pulse width is unimportant, for example. In double pulse mode, a second pulse is generated within every period at a set delay after the start of the first pulse. The delay is independently adjustable.
PERIOD, PULSE WIDTH, DELAY
Each parameter is variable within 8 overlapping decade ranges with a vernier providing continuously variable control within each range.
PERIOD
Range: 100nsec to 10sec (10MHz to 0·1Hz).
Jitter: <0.1%.
PULSE WIDTH
Range: 50nsec to 5sec
Jitter: <0.1%.
DELAY
Range: 50nsec to 5sec
TRIGGER, GATE
RUN
Normal operational mode in which pulses are generated continuously at 0.1Hz to 10MHz.
TRIGGERED
DC to 10MHz pulse train in synchronism with external trigger pulses; pulse width determined by pulse width controls. Trigger can be generated manually from front panel button.
GATED
0·1Hz to 10MHz pulse train, parameters set by period and pulse width controls, starts synchronously with leading edge of gate input. Last pulse is completed at the end of gating period. Gating signal can be generated manually from front panel button.
PULSE MODES
NORMAL PULSE
One pulse is generated each period. The delay setting is ignored.
SQUAREWAVE
0·1Hz to 10MHz squarewave, frequency set by the period controls. Pulse width and delay settings ignored.
Mark
Space ratio:
1:1 ±10%.
DOUBLE PULSE
A second pulse is generated after a delay set by the delay controls; the delay is related to the leading edge of the first pulse.
DELAYED PULSE
A pulse is generated after a delay set by the delay controls; the delay is related to rising edge of the trigger signal.
INPUTS
GATE/TRIG INPUT
Frequency range: DC - 10MHz
Signal range: TTL threshold; max. input ±10V.
Min. pulse width: >30nsec.
Input Impedance: Typically 10kW.
OUTPUTS
50W OUTPUT
Amplitude: Two switch selectable ranges of 0·1V - 1·0V and 1V - 10V from 50W. (50mV to 500mV and 500mV to 5V into 50W). Adjustable within ranges by a single turn vernier.
Rise/Fall Times: Typically 10nsec into 50Wload. Maximum 15ns.
Aberrations: Typically <5% for output set at >20% of range maximum, into 50W
AUX OUTPUT
Duplicates 50W output but at a fixed CMOS/TTL level.
SYNC OUTPUT
Amplitude: A positive going pulse at CMOS/TTL level.
Timing: Leading edge starts >20nsec before the TTL/50WW output transition.
Duration: Typically 30nsec.
COMPLEMENT SWITCH
Inverts the AUX and 50W outputs.
GENERAL
Power: 230V or 115V AC nominal 50/60Hz, adjustable internally; operating range ±14% of nominal; 20VA max.
Size: 140 x 220 x 230mm (HxWxD)
Weight: 1.6kg (3.5lb)
Operating Range: + 5°C to 40°C, 20-80% RH.
Storage Range: - 40°C to 70°C
Safety: Complies with EN61010-1.
EMC: Complies with EN55081-1 and EN50082-1.

Buďte prvý, kto napíše príspevok k tejto položke.

Nevypĺňajte toto pole: