TTi TS3022S - Laboratórny stabilizovaný zdroj s lineárnou reguláciou 30V/2A (120W)
Bench dc power supplies |




The Thurlby Thandar TS series of laboratory bench power supplies has become highly regarded throughout the world for its performance and reliability. High resolution controls enable precise setting of voltage and current levels whilst high accuracy digital meters provide clear, unambiguous readings. |
Constant voltage or constant current TS series units can operate in constant voltage or constant current mode (not TS3023 logic output). Remote sense for high current precision TS series units incorporate integrated band-gap reference diodes as the basis for stabilisation of both voltage and current. Remote sense terminals enable the precision to be maintained at high currents by eliminating the effects of connection lead resistance. Without remote sense, lead resistance of just a few tens of milliohms can seriously degrade regulation and produce misleading results. (Two cables of just 0.05W each will drop a total of 0.3V at 3 Amps) Safety and protection TS series PSUs are designed and built to meet the latest safety and EMC requirements. All outputs are fully protected against short circuits, external overvoltage and reverse voltage. |
Main Outputs | |
Voltage Setting: | By coarse and fine controls; resolution better than 5mV across the range. |
Current Setting: | By single logarithmic control. |
Output Mode: | The outputs operate in constant current or constant voltage mode with automatic cross-over. |
Output Switch: | Isolates the output and permits voltage and current limits to be set before connecting the load. |
Output Terminals: | 4mm terminals on 19mm (.75") spacing. |
Output Impedance: | CV - typically <5mW at 1kHz CI - typically >50kW. |
Output Protection: | Up to max. output voltage +20 Volts forward; diode clamped for reverse voltages at up to 3A. |
Load Regulation: | <0.01 % of max. output for 50% load change. |
Line Regulation: | <0.01 % of max. output for 10% line change. |
Remote Sense: | Eliminates up to 0.5V drop per lead. |
Ripple and Noise: | Typically <1mV rms. |
Transient Response: | <20usec to <50mV for 90% load change. |
Temp. Coefficient: | Typically <100ppm/°C. |
Meter Type: | Independent autoranging 12.5mm 3.5-digit LCDs for voltage and current indication. |
Meter Resolution: | Voltage - 10mV up to 20V, 100mV above 20V Current - 1mA up to 2A, 10mA above 2A. |
Meter Accuracy: | Voltage - 0.2% of reading + 1 digit. Current - 0.5% of reading + 1 digit. |
General | |
Input Voltage: | Internally set for 110, 120, 220, 240V; 50/60Hz. |
Input Voltage Range: | ± 10% of voltage setting. |
Power Consumption: | 150VA - single units, 300VA - dual/triple units. |
Operating Range: | 5°C to 40°C, 20% to 80% RH. |
Storage Range: | -20°C to +60°C. |
Electrical Safety: | Complies with EN61010-1. |
EMC: | Complies with EN55011 and EN50082-1. |
Size: | 160(W) x 160(H) x 238mm(D), single unit 308(W) x 160(H) x 238mm(D), dual unit |
Weight: | 4.9kg single, 9.6kg dual. |