Fluke Calibration 5644 - Standards Thermistor Probe

  • Accuracy to ± 0.001 °C

  • Affordable system accuracy to ± 0.004 °C or better

  • NIST-traceable calibration included from manufacturer; accredited Hart calibration optional
Dostupnosť Opýtajte sa
Možnosti doručenia
Kód: 1655457
€4 394,40 €3 662 bez DPH
Fluke Calibration 5644 - Standards Thermistor Probe
Fluke 5644 - referenčný termistor;Fluke 5644 - referenčný termistor
Cena na požiadanie
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

If you want a high-accuracy probe with excellent stability at a great price, the Model 5640-series Thermistor Standards Probes give you all three in a great package. Why pay for an SPRT when you can get ±0.001 °C accuracy from 0 °C to 60 °C in a calibrated thermistor probe for about one-third the cost of an uncalibrated SPRT alone? 

Each probe uses an ultra-stable glass thermistor enclosed in a thin-wall stainless steel tube. The basic semiconductor element is a bead of manganese, nickel, and cobalt oxides mounted on 0.1 mm platinum wires. For long-term stability, the thermistor is aged at various temperatures for 16 weeks. During the aging process, verification of the probe’s stability is done to ensure performance to published specs. 

The 5640, 5641, and 5642 thermistor probes are designed for the temperature range of 0 °C to 60 °C. The 5643 and 5644 probes span the 0 °C to 100 °C temperature range. They offer stability of either ±0.002 °C or ±0.005 °C. These stability levels are guaranteed for one full year. 

Precision calibration, traceable to NIST, is provided with each probe. A computer-generated table in increments of 0.01 °C is furnished with each calibration based on the formula: 

R=exp(A + B/T + C/T2 + D/T3)

The constants for the formula are obtained from a polynomial regression performed on the calibration data obtained. Over the range of 0 °C to 60 °C, calibration is performed at the triple point of water (0.01 °C) and 15 °C, 25 °C, 30 °C, 37 °C, 50 °C and 60 °C. For the 0 °C to 100 °C temperature range, the additional calibration points of 80 °C and 100 °C are used. 

Each probe is individually calibrated and includes a report of calibration from the manufacturer. Contact Hart for calibration in Hart’s NVLAP accredited lab. 

Thermistor standards are rugged, precision sensors suitable for use as secondary or working temperature standards for laboratory metrology applications. Because they generally are not affected by shock and vibration, you can use them in the most difficult field environments without worrying about calibration integrity. 

Combine these probes with Hart’s 1560 Black Stack thermometer to read directly in  °C,  °F, or K. This combination gives you resolution of 0.0001 degrees and total system accuracy is better than ±0.004 °C. 

Compare the cost of a 5640 calibrated probe and a Black Stack thermometer to the cost of one uncalibrated SPRT. Between 0 °C and 100 °C, nothing beats the value of the 5640 Series Thermistors. 

Specifications



Model


Diameter x Length



Range


Drift
°C/Year


Accuracy (Mfr.)
0–60 °C 60–100 °C



Wires

Nominal Resistance at 25 °C

5640

6.35 x 229 mm (0.25 x 9 in)

0 °C–60 °C

±0.005 °C

±0.0015 °C

n/a

4

4.4 kW

5641

3.18 x 114 mm (0.125 x 4.5 in)

0 °C–60 °C

±0.002 °C

±0.001 °C

n/a

4

5 kW

5642

3.18 x 229 mm (0.125 x 9 in)

0 °C–60 °C

±0.002 °C

±0.001 °C

n/a

4

4 kW

5643

3.18 x 114 mm (0.125 x 4.5 in)

0 °C–100 °C

±0.005 °C

±0.0015 °C

±0.0025 °C

4

10 kW

5644

3.18 x 229 mm (0.125 x 9 in)

0 °C–100 °C

±0.005 °C

±0.0015 °C

±0.0025 °C

4

10 kW

Does not include long-term drift.

Ordering Information

5640-X

Standards Thermistor Probe

5641-X

Standards Thermistor Probe

5642-X

Standards Thermistor Probe

5643-X

Standards Thermistor Probe

5644-X

Standards Thermistor Probe

X = termination. Specify “B” (bare wire), “D” (5-pin DIN for Tweener Thermometers), “G” (gold pins), “I” (INFO-CON for 1521 or 1522 Handheld Thermometers), “J” (banana plugs), “L” (mini spade lugs), “M” (mini banana plugs), or “S” (spade lugs).

Buďte prvý, kto napíše príspevok k tejto položke.

Nevypĺňajte toto pole: