Fluke Calibration 742A-25 - Resistor, DC Standard (25Ω)

  • Convenient air resistors don’t require oil or air baths
  • Calibrate resistance thermometers and other devices
  • Includes NIST-traceable calibration data with uncertainty to 1 ppm
  • Easily transported for on-site resistance calibration
Dostupnosť Opýtajte sa
Možnosti doručenia
Kód: 4923008
€8 169,60 €6 808 bez DPH
Fluke Calibration 742A-25 - Resistor, DC Standard (25Ω)
Fluke 742A
Cena na požiadanie
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

Do you need high-accuracy working standards for precise, on-site resistance calibrations? If you’d like to avoid maintaining traditional standard resistors in oil baths, Hart has a complete assortment of DC air resistors manufactured by Fluke, with Fluke’s proprietary tellurium-copper five-way binding posts. 

The Fluke 742A Series covers values from 1 ohm all the way to 10 megohm. These are the finest-quality air resistors you can buy. They’re durable, easy to maintain, and easy to use. Their excellent temperature stability allows them to be used from 18°C to 28°C with typically less than 2 ppm degradation. Using the calibration table supplied with the standards, which lists corrections in 0.5°C increments, this uncertainty can be reduced to near zero. 

Care has been taken to reduce resistance changes brought about by thermal and mechanical shock. Retrace (shift in resistance) is typically less than 2 ppm after cycling between 0°C and 40°C. 

Each of these resistors comes with a NVLAP-accredited report of calibration from Fluke. Accredited recalibrations are available from either Fluke or Hart. 

Specifications

Model


Nominal Value W

Stability, ppm
6 Months

Stability, ppm
12 Months

Max Change, ppm
from 23°C ±5°C (±ppm)

Calibration
Uncertainty, ±ppm

742A-1

1

5

8

3.0

1.0

742A-10

10

5

8

3.0

1.0

742A-25

25

5

8

3.0

1.0

742A-100

100

4

6

3.0

1.0

742A-1K

1K

4

6

2.0

1.5

742A-10K

10K

2.5

4

1.5

1.0

742A-100K

100K

4

6

2.0

2.5

742A-1M

1M

6

8

2.0

5.0

742A-10M

10M

6

9

3.0

10.0

742A-7002

Transit Case (holds two units)


Ordering Information

742A-1

Resistor, DC Standard, 1W

742A-10

Resistor, DC Standard, 10W

742A-25

Resistor, DC Standard, 25W

742A-100

Resistor, DC Standard, 100W

742A-1K

Resistor, DC Standard, 1 KW

742A-10K

Resistor, DC Standard, 10 KW

742A-100K

Resistor, DC Standard, 100 KW

742A-1M

Resistor, DC Standard, 1 MW

742A-10M

Resistor, DC Standard, 10 MW

742A-7002

Transit Case