Hart Scientific 9007 - Kalibračná piecka (–40 do 140 °C)
- Teplotný rozsah od –40 °C do 140 °C
- Vybavená dvoma 3-palcovými a 6-palcovými kalibračnými šachtami
![Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.](https://cdn.myshoptet.com/usr/www.elso.sk/user/banners/cart.png?65d4bf61)
![Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.](https://cdn.myshoptet.com/usr/www.elso.sk/user/banners/card.png?65d4c037)
![Tovar skladom odosielame v deň objednávky (do 13:00)](https://cdn.myshoptet.com/usr/www.elso.sk/user/banners/parcel.png?65d4c238)
![Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.](https://cdn.myshoptet.com/usr/www.elso.sk/user/banners/repair.png?65d4c103)
These calibrators cover temperatures from –40°C to 140°C, deliver the performance you’ll only find in true lab standards, and come in a totally portable case. If your work involves ocean vessels, aircraft, or service trucks, these dry-wells were designed for you. The U.S. Navy purchases the Model 9007 on contract N00244-00-D-0100.
The Model 9007 Dry-Well covers –40°C to 140°C. No external cooling is needed, so you get –40°C in normal ambient. Set-point accuracy is ±0.15°C and stability is better than ±0.02°C.
The dry-well comes with a unique NIST-traceable calibration at the full, six-inch depth of the well and at a three-inch depth for short probes. Coefficients for each calibration are stored in the dry-well and can be easily selected from the front-panel control buttons to match the length of the probe being tested.
Encased in all-aluminum enclosure that is durable, waterproof, and meets the standards of MIL-T-28800. Each unit comes with both RS-232 and IEEE-488 interface connections. A wide variety of inserts are available covering probe widths from 1/16" (1.6 mm) to 7/8" (22 mm).
Specifications |
|
Range |
–40 °C to 140 °C at 25 °C |
Accuracy |
±0.15 °C |
Stability |
±0.02 °C |
Heating Times |
25 °C to 140 °C: 20 min. |
Cooling Times |
25 °C to –40 °C: 25 min. |
Stabilization |
10 minutes |
Test Wells |
19 mm dia. x 152 mm deep (3/4 x 6 in) |
Communications |
RS-232 and IEEE-488 |
Enclosure |
Meets Type II, Class 3, Style D requirements of MIL-T-28800 |
Power |
115 VAC (±10 %), 3 A or 230 VAC (±10 %), 1.5 A, switchable, 50/60 Hz, 560 W |
Size (HxWxD) |
35.1 x 27.4 x 42.9 cm (13.8 x 10.8 x 16.9 in) |
Weight |
16.3 kg (36 lb.) |
NIST-Traceable Calibration |
Data at –40 °C, 0 °C, 25 °C, 75 °C, and 140 °C |
Ordering Information |
|
9007 |
Portable Lab Dry-Well, –40 °C to 140 °C, 1/4 in (6.36 mm) insert |
3107-2000 |
Blank insert |
3107-2063 |
1/16 in Insert (1.6 mm) |
3107-2125 |
1/8 in Insert (3.2 mm) |
3107-2156 |
5/32 in Insert (4 mm) |
3107-2188 |
3/16 in Insert (4.8 mm) |
3107-2250 |
1/4 in Insert (6.35 mm) |
3107-2313 |
5/16 in Insert (7.9 mm) |
3107-2375 |
3/8 in Insert (9.5 mm) |
3107-2500 |
1/2 in Insert (12.7 mm) |
3107-2625 |
5/8 in Insert (15.9 mm) |
3107-2901 |
1 User-Specified Hole |
3107-2902 |
2 User-Specified Holes |