Hart Scientific 2001-7080 - Standard Bath (–80°C to 110°C)

Značka: Fluke
  • Self-contained refrigeration—no LN2 or chiller required
  • Temperatures as low as –100 °C in real metrology baths
  • Best stability and uniformity available at –60 °C and below
  • Large working areas for increased throughput
Dostupnosť Na objednávku
Môžeme doručiť do:
16.8.2024
Možnosti doručenia
Kód: 747
€1 €0,83 bez DPH
Hart Scientific 2001-7080 - Standard Bath (–80°C to 110°C)
Značka: Fluke
Hart Scientific 2001-7080 - Standard Bath (–80°C to 110°C)
Ukončená výroba
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

Do you need a bath that chills below –40 °C to temperatures as low as –60 °C or even –100 °C? Would you like a bath that reaches those temperatures without using any external coolants? Hart has a variety of baths that meet these temperature requirements and give you the best stability in the industry. 

These baths are completely self-contained. They require no auxiliary cooling fluids or devices to achieve their set-point temperatures. Using Hart’s unique “heat-port” design, stability at –100 °C is ±0.0025 °C. No other company makes a bath that can match a Hart bath’s performance, and Hart baths are backed by our guarantee that if they don’t perform exactly the way we say they will, we’ll take them back. No arguments. No ifs, ands, or buts. 

Automate each of these baths with an interface package and Hart’s 9930 Interface-it software. If you want to completely automate the entire calibration process, see the description of Hart’s MET/TEMP II software package. 

Forget commodity-like utility baths! They’re not designed for high performance calibration needs. And be careful of companies that advertise performance specifications they don’t meet. It’s easy to write down numbers; it’s more difficult to meet them with an instrument. 

Remember, if our baths don’t perform the way we say they will, just send them back. Our equipment won’t disappoint you. 

Hart sells a complete selection of fluids for your bath. You can find these here.

Specifications

7060 7080 7100

Range

–60 °C to 110 °C

–80 °C to 110 °C

–100 °C to 110 °C

Stability

±0.0025 °C at –60 °C
(methanol)
±0.002 °C at 0 °C
(methanol)
±0.0015 °C at 25 °C
(water)
±0.003 °C at 100 °C
(oil 5012)

±0.0025 °C at –80 °C
(methanol)
±0.0015 °C at 0 °C
(methanol)
±0.0015 °C at 25 °C
(water)
±0.003 °C at 100 °C
(oil 5012)

±0.008 °C at –100 °C
(methanol)

Uniformity

±0.005 °C at –60 °C
(methanol)
±0.005 °C at 0 °C
(methanol)
±0.003 °C at 25 °C
(water)
±0.005 °C at 100 °C
(oil 5012)

±0.007 °C at –80 °C
(methanol)
±0.005 °C at 0 °C
(methanol)
±0.003 °C at 25 °C
(water)
±0.005 °C at 100 °C
(oil 5012)

±0.005 °C at –100 °C
(methanol)

Temperature Setting

Digital display with push-button data entry

Set-Point Resolution

0.01 °C; high-resolution mode, 0.00007 °C

Display Resolution

0.01 °C

Digital Setting Accuracy

±1 °C

Digital Setting Repeatability

±0.01 °C

Heaters

500 and 1000 Watts

350 and 700 Watts

Access Opening

127 x 254 mm (5 x 10 in)

98 mm diameter (3.8 in)

Depth

305 mm (12 in)

406 mm (16 in)

Wetted Parts

304 stainless steel

Power

230 VAC (±10 %), 50 or 60 Hz, 13 A, single phase, specify frequency

230 VAC (±10 %), 50 or 60 Hz, 12 A, specify frequency

Volume

27 liters (7.2 gallons)

18 liters (4.8 gallons)

Weight

159 kg (350 lb.)

182 kg (400 lb.)

Size (HxWxD)

1168 x 775 x 483 mm
(46 x 30.5 x 19 in)

1270 x 813 x 483 mm
(50 x 32 x 19 in)

Automation Package

Interface-it software and an RS-232 computer interface are available for setting the bath temperature via an external computer. For IEEE-488, add 2001-IEEE to the automation package.

Ordering Information

7060

Standard Bath, –60 °C to 110 °C

7080

Standard Bath, –80 °C to 110 °C

7100

Standard Bath, –100 °C to 110 °C

2001-7060

Automation Package for 7060

2001-7080

Automation Package for 7080

2001-7100

Automation Package for 7100

2001-IEEE

Add for IEEE-488 (requires Automation Package)

2010

Access Cover, 127 x 254 mm (5 x 10 in), Lexan

2007

Access Cover, 127 x 254 mm (5 x 10 in), Stainless Steel

2016-7060

Fluid Level Adapter, 7060

2016-7080

Fluid Level Adapter, 7080

2019-7100

Fluid Level Adapter, 7100

2069

8X Magnifier Scope, with mounts

2030

Fast-Start Cooler

Buďte prvý, kto napíše príspevok k tejto položke.

Nevypĺňajte toto pole: